Incessant form of a benign arrhythmia in a patient with a DDD pacemaker.
 
More details
Hide details
1
2nd Department of Coronary Artery Disease Institute of Cardiology
 
 
Publication date: 2017-01-31
 
 
Corresponding author
Aleksander Maciąg   

2nd Department of Coronary Artery Disease Institute of Cardiology, Sprtańska 1 Str., 02-637 Warsaw, Poland
 
 
Heart Beat 2016;1:61–62
 
KEYWORDS
TOPICS
ABSTRACT
Authors present the case of an 83-year old male with the dual chamber pacemaker implanted due to a tachycardia-bradycardia syndrome and with an incessant form of atrioventricular nodal re-entrant tachycardia (AVNRT). Intracardiac electrogram with the retrograde atrial depolarization helps to establish the diagnosis of the AVNRT. In order to prevent tachycardiomiopathy and to avoid reduced health-related quality of life it had been decided to perform an early successful radiofrequency ablation.